Bryan Donkin Slam Shut Valves are specifically designed to
protect downstream equipment from either under or over pressure
conditions. For instance, a slam shut can be used to mechanically
isolate a gas system should the pressure exceed a given value
(over pressure cut off or OPCO). A slam shut can also be used
to mechanically shut off a gas system should the pressure
fall below a given value which may happen if a gas line is
severed (under pressure cut off or UPCO). In addition, slam
shuts can be fitted with thermal links that will shut the
valve in the case of a fire. Models 209 and 309 series are
available incorporated with many of our pressure regulating
valves as an option to enhance the regulators features, or
independently mounted on its own body. Use with confidence
with natural gas and all other non-corrosive gases.
 |
Model 290
Description : The Model 290 is only available with
over pressure cut-off (OPCO) protection.
| Threaded Size |
: 1/2", 3/4", 1",
1-1/4", 1-1/2" & 2" |
| Pressure |
: Up to 375 PSIG |
| Flanged Sizes |
: 1" and 2" |
|
| |
Download
PDF |
| |
|
| |
|
| |
|
 |
Model 309LP
Description : The Series 309 are available with
over pressure cut-off (OPCO) or both under and over
pressure cut-off protection (UPCO/OPCO).
| Threaded Size |
: 1/2", 3/4", 1",
1-1/4", 1-1/2" & 2" |
| Pressure |
: Up to 150 PSIG |
| Flanged Sizes |
: 1" and 2" |
|
| |
Download
PDF |
| |
|
| |
|
 |
Model 309LP2
Description : The Series 309 are available
with over pressure cut-off (OPCO) or both under and
over pressure cut-off protection (UPCO/OPCO).
| Threaded Size |
: 1/2", 3/4", 1",
1-1/4", 1-1/2" & 2" |
| Pressure |
: Up to 275 PSIG |
| Flanged Sizes |
: 1" and 2" |
|
| |
Download
PDF |
| |
|
| |
|
 |
Model 309LP4
Description : The Series 309 are available
with over pressure cut-off (OPCO) or both under and
over pressure cut-off protection (UPCO/OPCO).
| Threaded Size |
: 1/2", 3/4", 1",
1-1/4", 1-1/2" & 2" |
| Pressure |
: Up to 275 PSIG |
| Flanged Sizes |
: 1" and 2" |
|
| |
Download
PDF |
| |
Go to top |
| |
|
 |
Model 303
Description : Designed to safeguard gas
distribution systems, normally installed upstream of
the regulator with the externalcontrol line piped to
the downstream of the regulator, closing automatically
in the event of an overpressure condition. Integral
push-button type pressure equalizing valve, manual reset,
UPCO low pressure loss, completely self-acting, no external
power supply required.
| Pressure |
: Up to 275 PSIG |
| Flanged Sizes |
: 6" to 12" |
|
| |
Download
PDF |
| |
|
| |
|
 |
Model 304
Description : Designed to safeguard
gas distribution systems, normally installed upstream
of the regulator closing automatically in the event
of temporary interruption of the power supply to the
solenoid. Accurate and dependable action, integral push-button
type pressure, equalizing valve manual reset, UPCO low
pressure loss, and flameproof.
| Pressure |
: Up to 230 PSIG |
| Flanged Sizes |
: 2" to 8" |
|
| |
Download
PDF |
| |
|
| |
|
 |
Model 305
Description : Designed to safeguard
gas distribution systems, normally installed upstream
of the regulator with the external control line piped
to the downstream of the regulator, closing automatically
in the event of an overpressure condition. Fully enclosed
color coded valve position indicator, integral push-button
type pressure equalizing valve, manual reset, low pressure
loss.
| Pressure |
: Up to 230 PSIG |
| Flanged Sizes |
: 2" to 8" |
|
| |
Download
PDF |
| |
|
| |
Go to top |
| |
|
|